BCH800 – BCH1K -RM

2U Rack Mount Battery Charger / Power Supply 800W – 1000W

The BCH800-1K series battery charger is a rugged, industrial-grade product, using field-proven design suitable for use in DC battery backup applications.It is a mature product providing excellent reliability and performance and delivering up to 1000 watts of output power with convection/conduction cooling NO Fans.

The two alarms provide external monitoring of Power Fail / Charger Fail and Battery Low via voltage free contacts.

The chassis-mount design feature allows for easy mounting.

Additional ruggedizing and conformal coating are available for applications requiring higher immunity to shock, vibration, humidity, moisture, dust and insects.

Main Features

  • 2UV,  x 19in Rack Mount
  • 24V, 48V, 96V or 108VDC output voltage options
  • Convection cooled: No fans
  • Two power levels: 800 & 1000 watts
  • Fully isolated input – output
  • Overvoltage, Overload and short circuit protection
  • Inrush current limiting
  • MTBF > 150,000hrs
  • Any output from 24vdc ~ 120vdc possible
  • Power Fail / Charger Fail Alarm
  • Battery Low Alarm

Options

  • TBC Temperature Battery Compensation Charging
  • TIM Automatic Battery Testing
  • Boost A variety of boost options
  • Various circuit breakers options
  • Digital Meters

SERIES TABLE

ModelOutput  NomFloat VCurrent  Power
RM-BCH800-28FT24 V27.6 V29A800W
RM-BCH800-55FT48 V55.2 V14A800W
RM-BCH1K-110FT96 V108 V8.0A990W
RM-BCH1K-110FT108 V124 V8.0A990W
For Digital Meters, change part no to: RMM-BC800-xxx    / RMM-BCH1K-xxx
110V model adjustable for use on 96V or 108V nominal battery systems

SPECIFICATIONS TABLE

Input Voltage230VAC ( 190 ~ 264 )
Input Frequency 47 ~ 63Hz
Input Current9.5A
Input ProtectionInrush current limiting
Transient protection / Varistors
Internal safety fuse
Output VoltageRefer to table
Overload
Protection
Constant current limiting with short circuit
protection.Battery must be externally fused.
EfficiencyTypically 80%
Overvoltage
Protection
Constant current limiting with short circuit
protection.
Battery must be externally fused
Parallel OperationYes.
Switching Freq.Typically 55KHz
Operating Temp.0ºC to +50ºC at full load.
Derate 2.5% per ºC to +70ºC
CoolingConduction / convection cooled via base plate
Humidity5-95% non-condensing
Ripple & NoiseTypically <1% of output voltage
InsolationInput-Output: 3Kvac,
Input-Frame Ground: 2kVAC
Output-Frame Ground: 500VAC.
EMCEN55022 Class A
ImmunityEN 61000-4-2 (ESD)
EN 61000-4-3 (RF Immunity)
EN 61000-4-4 (Fast Transients)
EN 61000-4-6 (Conducted Imm.)
MTBF>150,000hrs @ 45ºC
Dimensions2U x 19in x 420mm Rack Mount

Ask for Assistance

Selecting the right power supply for your application is not a small task. Let our technical sales engineers guide you through the process of choosing the right solution for your needs.

Below some parameters usually required to size and select the right power supply:

  • Power & control requirements
  • Output & Input Voltage / Multioutput Voltage / Variable Voltage
  • Redundancy level
  • Mounting
  • Inrush Current
  • Environmental specifications (Temperature, altitude, vibration, shock)
  • Specific Industries Standards (Railway, Military, Medical)

Contact Our Team

Email us at sales@heliosps.com.au, we will get back as soon as we can.

You may also like...