$224.62
SKU | Stock | Power Battery Charger | Output Voltage Battery Charger | Price | Quantity | ||
---|---|---|---|---|---|---|---|
EN54-27V6-5A | Out of Stock - Please contact our Office | 110W | 24V | $224.62 |
The EN54 Series is a new generation / smart Power Supply that is designed to provide battery backed-up power in the event of either the PSU or the battery being disconnected or short-circuited.
When the AC supply fails, the battery will automatically be connected and will provide power until the ac supply is restored.. If the battery has reached its disconnect voltage, it will automatically be disconnected to prevent deep discharge damage.
Designed for powering critical loads with battery back-up, in a wide range of Industrial applications and in particular Security installations and Access Control, with separate Load and Battery Charging circuits.
A wide range of Signals, Led’s and Alarms, all aimed at providing the optimum solution for powering critical DC Loads.
An isolated Common Fault relay has been provided which will operate if any fault is found (This is a fail-safe signal so will signal a fault even if no power sources are on/connected.
Weight | N/A |
---|---|
Dimensions | N/A |
INPUT | |
Input voltage | 200 – 240 Vac +/-10% |
Frequency Range | 50-60Hz |
Temperature Range | 0 – 50ºC ambient (Convection cooled, cased) |
Input fuse | T2H 250V TR5 |
Input Current | 1.6Arms (200Vacin, full load) |
Hold-up Time | 30mS (230Vacin, full load, no battery connected) |
Power Factor | 0.45 (230Vacin, Full load) |
No Load Power | 1.5W (230Vacin) |
Start-up | Less than 1.5 seconds |
OUTPUT | |
Output Voltage | 27.6V (factory set for operation with thermistor) |
Output Current | 4A |
Power limit | 115% +/-10% |
80-85% Typ.@ 230Vacin, Full load | |
OVP | 105-125% (latching and non dissipative) recycle input to restart |
Short Circuit protection | Hiccup mode |
Signals | Mains Fail, Battery O/C, Charger Loss, Battery Low- LED’s & open collector – 100mA sink, Status LED Green = Flashing = OK Common Fault (Volt free) relay 2x Customer options – open collector – 30mA sink HiZ indication =0.6J Battery Powerfail signal = 100mS |
Current limit | Primary side power limit |
Thermal protection | Primary side thermal protection (non-latching) |
Load regulation | +/- 0.75% |
Line regulation | +/- 0.5% |
Noise & ripple | 0.5% (230Vacin, Full load, BW = DC – 10MHz) |
BATTERY | |
Charger | Current limited @ 1 A |
Temp compensation | Connector provided for user to add 100KΩ thermistor (β=4400) Suitable for standby use |
Deep discharge protection | 21V +/-0.25V |
Selecting the right power supply for your application is not a small task. Let our technical sales engineers guide you through the process of choosing the right solution for your needs.
Below some parameters usually required to size and select the right power supply:
Contact our team of experienced engineers to discuss your unique power conversion and backup needs. We offer a wide range of highly reliable components that can be integrated and customized to create a solution that meets or exceeds your requirements.
For power automation systems please contact us at power.systems.automation@heliosps.com.au
© Copyright Helios Power Solutions 2024