Perfect chargers for any type of battery

Charge voltage can be precisely adjusted to suit any sealed or unsealed battery system.In particular, sealed maintenance free batteries must be charged correctly in order to ensure a long
service life. Overvoltage will result in excessive gassing and venting of a sealed battery. The battery will dry out and fail.

Suitable for AC and DC supply (AC-DC and DC-DC operation)

Except for the 3-phase input models, the chargers also accept a DC supply.

Controlled charging

Every TG Charger has a microprocessor, which accurately controls the charging in three steps. The charging process takes place in accordance with the IUoUo characteristic and charges more rapidly than
other processes.

Use of TG Chargers as a power supply

As a result of the perfectly stabilized output voltage, a TG Charger can be used as a power supply if batteries or large buffer capacitors are not available.

Two outputs to charge 2 battery banks (24 V models only)

The TG Chargers feature 2 isolated outputs. The second output, limited to approximately 4 A and with a slightly lower output voltage, is intended to top up a starter battery.

To increase battery life: temperature compensation

Every Skylla TG Charger comes with a battery temperature sensor. When connected, charge voltage will automatically decrease with increasing battery temperature. This feature is especially recommended for
sealed batteries which otherwise might be overcharged and dry out due to venting.

Battery voltage sense

In order to compensate for voltage loss due to cable resistance, TG Chargers are provided with a voltage sense facility so that the battery always receives the correct charge voltage.

SERIES TABLE

Model Input Voltage Range (VAC)  Input Voltage Range (VDC)  Battery Capacity (Ah)
24/30 TG
24/50 TG
185-264 180-400 150-500
24/50 TG
3 phase
320-450 NA 250-500
24/80 TG 185-264 180-400 400-800
24/100 TG 185-264 180-400 500-1000
24/100 TG
3 phase
320-450 NA 500-1000
48/25 TG 185-264 180-400 125-250
48/50 TG 185-264 180-400 250-500

SPECIFICATIONS TABLE

Input voltage (VAC) 230 V or 3X400 VAC
Frequency (Hz) 45-65
Power factor 1
Temperature sensor YES
Can be used as power supply YES
Remote alarm Forced cooling Potential free contacts 60 V / 1 A (1x NO and 1x NC)
Protection Output short circuit
Battery reverse polarity detection                                                       Battery voltage too high
Temperature too high
Operating temp.  -40 to +50°C (-40 – 122°F)
 range Humidity (non condensing) max 95%
Battery-connection M8 studs