The Genesys™ 3U Full-Rack (GEN-3U) series of 15kW DC Programmable Power Supplies provides high power density (up to 15kW) with a complete set of user-friendly interfaces within a 3U profile.

This series offers Output voltages from 30V (@ 500A) to 1500V (@ 10.0A) in a Three-phase 208VAC Input (180-253VAC, 47-63Hz), a Three-phase 400VAC Input (342-440VAC, 47-63Hz) and a Three-phase 480VAC Input (432-528VAC, 47-63Hz) all with Passive Power-Factor Correction (0.88 @ rated load).

Multiple remote programming methods are available including the built-in Remote Analog Program/Monitor and Remote Digital Serial Communication (RS-232/RS-485) Interfaces along with the optional LXI certified LAN, IEEE (IEEE 488.2 & SCPI compliant) and Isolated Analog (5V/10V and 4-20mA) Interfaces.

SERIES TABLE

Model Output Voltage (Vdc) Output Current (Adc) Output Power (kW)
GEN 7.5-1000 0~7.5 0~1000 7.5
GEN 10-1000 0~10 0~1000 10
GEN 12.5-800 0~12.5  0~800 10
GEN 20-500 0~20 0~500 10
GEN 25-400 0~25 0~400 10
GEN 30-333 0~30 0~333 10
GEN 30-500 0~30 0~500 15
GEN 40-250 0~40 0~250 10
GEN 40-375 0~40 0~375 15
GEN 50-200 0~50 0~200 10
GEN 50-300 0~50 0~300 15
GEN 60-167 0~60 0~167 10
GEN 60-250 0~60 0~250 15
GEN 80-125 0~80 0~125 10
GEN 80-187.5 0~80 0~187.5 15
GEN 100-100 0~100 0~100 10
GEN 100-150 0~100 0~150 15
GEN 125-80 0~100 0~80 10
GEN 125-120 0~100 0~120 15
GEN 150-66 0~125 0~66 10
GEN 150-100 0~125 0~100 15
GEN 200-50 0~150 0~50 10
GEN 200-75 0~150 0~75 15
GEN 250-40 0~250 0~40 10
GEN 250-60 0~250 0~60 15
GEN 300-33 0~300 0~33 10
GEN 300-50 0~300 0~50 15
GEN 400-25 0~400 0~25 10
GEN 400-37.5 0~400 0~37.5 15
GEN 500-20 0~500 0~20 10
GEN 500-30 0~500 0~30 15
GEN 600-17 0~600 0~17 10
GEN 600-25 0~600 0~25 15
GEN 800-12.5 0~800 0~12.5 10
GEN 800-18.8 0~800 0~18.8 15
GEN 1000-10 0~1000 0~10 10
GEN 1000-15 0~1000 0~15 15
GEN 1250-8 0~1250 0~8 10
GEN 1250-12 0~1250 0~12 15
GEN 1500-6.7 0~1500 0~6.7 10
GEN 1500-10 0~1500 0~10 15

SPECIFICATIONS TABLE

Input Voltage / Frequency (range) 208VAC (180-253), 400VAC (360-440 , 342-440 (select 10kW/15kW models)), 480VAC (432-528); 47-63Hz (all)
No. of phases 3-Phase (Wye or Delta) 4 wire total (3-Phase and 1 protective Earth ground)
Dropout Voltage 180 / 360, 342 (select models) / 432; select models (10kW): 800V-1500V, select models (15kW): 30V-50V, 800V-1500V
Input Current (180VAC/360 or 342VAC/432VAC) 10kW – 45/23/20 (Vout < 600V); N/A/23/20 (800V < Vout < 1500V) – at full rated Output power 15kW – 64/32/27 (Vout < 600V); N/A/32/27 (800V < Vout < 1500V) – at full rated Output power
Inrush Current Not to exceed full rated Input current (see para. above)
Power Factor 0.88 Passive (typical)
Leakage Current 3.5 (EN60950) max.
Input Protection 208VAC: circuit breaker (Vout < 600V); 400VAC/480VAC (all models) – line fuse
Input Overvoltage Protection Unit shall not be damaged by line overvoltage of 120% nominal AC input voltage with maximum duration of 100usec.
Phase Imbalance ≤ 5% on Three-Phase Input
Operating Temperature 0 ~ +50°C, 100% load
Storage Temperature -20 ~ +70°C
Operating Humidity 20 ~ 80% RH (non-condensing)
Storage Humidity 10 ~ 90% RH (non-condensing)
Vibration & Shock ASTM D4169, Standard Practice for Performance Testing of Shipping Containers and Systems, Shipping Unit: Single Package Assurance Level: Level II; Acceptance Criteria: Criterion 1 – No product damage Criterion 2 – Packaging is intact, Distribution Cycle: 12 – Air (intercity) and motor freight (local), unitized is used.
Altitude Operating: +50°C up to 7500 ft. (2500m), +45°C from 7501 to 10,000ft (2501m – 3000m), Non-Operating 40,000 ft (12,000m)
Audible Noise 65dBA at Io(rated) (measured 1m from front panel)