Our website features a wide range of standard power conversion and backup products, but we also have the capacity and capability to design and manufacture custom solutions to meet your specific application needs. Contact our team of experienced engineers today to discuss your project. Dismiss
The TDK – Lambda Genesys™ 3U Full-Rack (GEN-3U) series of 15kW DC Programmable Power Supplies provides high power density (up to 15kW) with a complete set of user-friendly interfaces within a 3U profile.
This series offers Output voltages from 30V (@ 500A) to 1500V (@ 10.0A) in a Three-phase 208VAC Input (180-253VAC, 47-63Hz), a Three-phase 400VAC Input (342-440VAC, 47-63Hz) and a Three-phase 480VAC Input (432-528VAC, 47-63Hz) all with Passive Power-Factor Correction (0.88 @ rated load).
Multiple remote programming methods are available including the built-in Remote Analog Program/Monitor and Remote Digital Serial Communication (RS-232/RS-485) Interfaces along with the optional LXI certified LAN, IEEE (IEEE 488.2 & SCPI compliant) and Isolated Analog (5V/10V and 4-20mA) Interfaces.
Model | Output Voltage (Vdc) | Output Current (Adc) | Output Power (kW) |
GEN 7.5-1000 | 0~7.5 | 0~1000 | 7.5 |
GEN 10-1000 | 0~10 | 0~1000 | 10 |
GEN 12.5-800 | 0~12.5 | 0~800 | 10 |
GEN 20-500 | 0~20 | 0~500 | 10 |
GEN 25-400 | 0~25 | 0~400 | 10 |
GEN 30-333 | 0~30 | 0~333 | 10 |
GEN 30-500 | 0~30 | 0~500 | 15 |
GEN 40-250 | 0~40 | 0~250 | 10 |
GEN 40-375 | 0~40 | 0~375 | 15 |
GEN 50-200 | 0~50 | 0~200 | 10 |
GEN 50-300 | 0~50 | 0~300 | 15 |
GEN 60-167 | 0~60 | 0~167 | 10 |
GEN 60-250 | 0~60 | 0~250 | 15 |
GEN 80-125 | 0~80 | 0~125 | 10 |
GEN 80-187.5 | 0~80 | 0~187.5 | 15 |
GEN 100-100 | 0~100 | 0~100 | 10 |
GEN 100-150 | 0~100 | 0~150 | 15 |
GEN 125-80 | 0~100 | 0~80 | 10 |
GEN 125-120 | 0~100 | 0~120 | 15 |
GEN 150-66 | 0~125 | 0~66 | 10 |
GEN 150-100 | 0~125 | 0~100 | 15 |
GEN 200-50 | 0~150 | 0~50 | 10 |
GEN 200-75 | 0~150 | 0~75 | 15 |
GEN 250-40 | 0~250 | 0~40 | 10 |
GEN 250-60 | 0~250 | 0~60 | 15 |
GEN 300-33 | 0~300 | 0~33 | 10 |
GEN 300-50 | 0~300 | 0~50 | 15 |
GEN 400-25 | 0~400 | 0~25 | 10 |
GEN 400-37.5 | 0~400 | 0~37.5 | 15 |
GEN 500-20 | 0~500 | 0~20 | 10 |
GEN 500-30 | 0~500 | 0~30 | 15 |
GEN 600-17 | 0~600 | 0~17 | 10 |
GEN 600-25 | 0~600 | 0~25 | 15 |
GEN 800-12.5 | 0~800 | 0~12.5 | 10 |
GEN 800-18.8 | 0~800 | 0~18.8 | 15 |
GEN 1000-10 | 0~1000 | 0~10 | 10 |
GEN 1000-15 | 0~1000 | 0~15 | 15 |
GEN 1250-8 | 0~1250 | 0~8 | 10 |
GEN 1250-12 | 0~1250 | 0~12 | 15 |
GEN 1500-6.7 | 0~1500 | 0~6.7 | 10 |
GEN 1500-10 | 0~1500 | 0~10 | 15 |
Input Voltage / Frequency (range) | 208VAC (180-253), 400VAC (360-440 , 342-440 (select 10kW/15kW models)), 480VAC (432-528); 47-63Hz (all) |
No. of phases | 3-Phase (Wye or Delta) 4 wire total (3-Phase and 1 protective Earth ground) |
Dropout Voltage | 180 / 360, 342 (select models) / 432; select models (10kW): 800V-1500V, select models (15kW): 30V-50V, 800V-1500V |
Input Current (180VAC/360 or 342VAC/432VAC) | 10kW – 45/23/20 (Vout < 600V); N/A/23/20 (800V < Vout < 1500V) – at full rated Output power 15kW – 64/32/27 (Vout < 600V); N/A/32/27 (800V < Vout < 1500V) – at full rated Output power |
Inrush Current | Not to exceed full rated Input current (see para. above) |
Power Factor | 0.88 Passive (typical) |
Leakage Current | 3.5 (EN60950) max. |
Input Protection | 208VAC: circuit breaker (Vout < 600V); 400VAC/480VAC (all models) – line fuse |
Input Overvoltage Protection | Unit shall not be damaged by line overvoltage of 120% nominal AC input voltage with maximum duration of 100usec. |
Phase Imbalance | ≤ 5% on Three-Phase Input |
Operating Temperature | 0 ~ +50°C, 100% load |
Storage Temperature | -20 ~ +70°C |
Operating Humidity | 20 ~ 80% RH (non-condensing) |
Storage Humidity | 10 ~ 90% RH (non-condensing) |
Vibration & Shock | ASTM D4169, Standard Practice for Performance Testing of Shipping Containers and Systems, Shipping Unit: Single Package Assurance Level: Level II; Acceptance Criteria: Criterion 1 – No product damage Criterion 2 – Packaging is intact, Distribution Cycle: 12 – Air (intercity) and motor freight (local), unitized is used. |
Altitude | Operating: +50°C up to 7500 ft. (2500m), +45°C from 7501 to 10,000ft (2501m – 3000m), Non-Operating 40,000 ft (12,000m) |
Audible Noise | 65dBA at Io(rated) (measured 1m from front panel) |
Selecting the right power supply for your application is not a small task. Let our technical sales engineers guide you through the process of choosing the right solution for your needs.
Below some parameters usually required to size and select the right power supply:
Contact our team of experienced engineers to discuss your unique power conversion and backup needs. We offer a wide range of highly reliable components that can be integrated and customized to create a solution that meets or exceeds your requirements.