GEN2.4 kW

TDK – Lambda Laboratory Power Supplies: 2.4 kW

The Genesys – TDK Lambda 1U Full-Rack (GEN-1U) series of 2400W DC Programmable Power Supplies provides high power density (up to 2400W) with a complete set of user-friendly interfaces within a 1U (1.75″) profile.

This series offers Output voltages from 8V (@ 300A) to 600V (@ 4.0A) in both Single-phase 230VAC Input (175-265VAC, 47-63Hz) with Active Power-Factor Correction (0.99 @ rated load) and Three-phase 208VAC Input (175-265VAC, 47-63Hz) with Active Power-Factor Correction (0.94 @ rated load) and two Auxiliary Outputs (15.0V @ 0.2A and 5.0V @ 0.2A) for use with Remote Analog Control/Status.

Multiple remote programming methods are available including the built-in Remote Analog Program/Monitor and Remote Digital Serial Communication (RS-232/RS-485) Interfaces along with the optional LXI certified LAN, IEEE (IEEE 488.2 & SCPI compliant) and Isolated Analog (5V/10V and 4-20mA) Interfaces.

SERIES TABLE

ModelOutput Voltage (VDC)Output Current ( A )Output Power ( W )
GEN 8-3000~8V0~3002400
GEN 10-2400~10V0~2402400
GEN 16-1500~16V0~1502400
GEN 20-1200~20V0~1202400
GEN 30-800~30V0~802400
GEN 40-600~40V0~602400
GEN 60-400~60V0~402400
GEN 80-300~80V0~302400
GEN 100-240~100V0~242400
GEN 150-160~150V0~162400
GEN 300-80~300V0~82400
GEN 600-40~600V0~42400

SPECIFICATIONS TABLE

Input Voltage / Frequency (range)Single Phase,230V models: 170~265Vac, 47~63Hz,3-Phase, 208V models: 170~265Vac,  47~63Hz
Inrush CurrentSingle-Phase and 3-Phase 208V models: Less than 50A
Power FactorSingle Phase models: 0.99@230Vac, rated output power. 3-Phase models: 0.94@208Vac, rated output power.
Parallel OperationUp to 4 identical units in master/slave mode
Series OperationUp to 2 identical units. with external diodes. 600V Max to Chassis ground
Operating temp0~50°C, 100% load.
Storage temp-20~85°C
Operating humidity20~90% RH (non-condensing).
Storage humidity10~95% RH (non-condensing).
VibrationMIL-810F, method 514.5 , The EUT is fixed to the vibrating surface.
ShockLess than 20G , half sine, 11mSec. Unit is unpacked.
AltitudeOperating: 10000ft (3000m), Derate output current by 2%/100m above 2000m, Alternatively, derate maximum ambient temp.
by 1ºC/100m above 2000m. Non operating: 40000ft (12000m).
RoHS ComplianceComplies with the requirements of RoHS directive.

Ask for Assistance

Selecting the right power supply for your application is not a small task. Let our technical sales engineers guide you through the process of choosing the right solution for your needs.

Below some parameters usually required to size and select the right power supply:

  • Power & control requirements
  • Output & Input Voltage / Multioutput Voltage / Variable Voltage
  • Redundancy level
  • Mounting
  • Inrush Current
  • Environmental specifications (Temperature, altitude, vibration, shock)
  • Specific Industries Standards (Railway, Military, Medical)
  • Terminals

Contact Our Team

Contact our team of experienced engineers to discuss your unique power conversion and backup needs. We offer a wide range of highly reliable components that can be integrated and customized to create a solution that meets or exceeds your requirements.

For power automation systems please contact us at power.systems.automation@heliosps.com.au

You may also like...