Our website features a wide range of standard power conversion and backup products, but we also have the capacity and capability to design and manufacture custom solutions to meet your specific application needs. Contact our team of experienced engineers today to discuss your project. Dismiss
The Genesys – TDK Lambda 1U Full-Rack (GEN-1U) series of 2400W DC Programmable Power Supplies provides high power density (up to 2400W) with a complete set of user-friendly interfaces within a 1U (1.75″) profile.
This series offers Output voltages from 8V (@ 300A) to 600V (@ 4.0A) in both Single-phase 230VAC Input (175-265VAC, 47-63Hz) with Active Power-Factor Correction (0.99 @ rated load) and Three-phase 208VAC Input (175-265VAC, 47-63Hz) with Active Power-Factor Correction (0.94 @ rated load) and two Auxiliary Outputs (15.0V @ 0.2A and 5.0V @ 0.2A) for use with Remote Analog Control/Status.
Multiple remote programming methods are available including the built-in Remote Analog Program/Monitor and Remote Digital Serial Communication (RS-232/RS-485) Interfaces along with the optional LXI certified LAN, IEEE (IEEE 488.2 & SCPI compliant) and Isolated Analog (5V/10V and 4-20mA) Interfaces.
Model | Output Voltage (VDC) | Output Current ( A ) | Output Power ( W ) |
GEN 8-300 | 0~8V | 0~300 | 2400 |
GEN 10-240 | 0~10V | 0~240 | 2400 |
GEN 16-150 | 0~16V | 0~150 | 2400 |
GEN 20-120 | 0~20V | 0~120 | 2400 |
GEN 30-80 | 0~30V | 0~80 | 2400 |
GEN 40-60 | 0~40V | 0~60 | 2400 |
GEN 60-40 | 0~60V | 0~40 | 2400 |
GEN 80-30 | 0~80V | 0~30 | 2400 |
GEN 100-24 | 0~100V | 0~24 | 2400 |
GEN 150-16 | 0~150V | 0~16 | 2400 |
GEN 300-8 | 0~300V | 0~8 | 2400 |
GEN 600-4 | 0~600V | 0~4 | 2400 |
Input Voltage / Frequency (range) | Single Phase,230V models: 170~265Vac, 47~63Hz,3-Phase, 208V models: 170~265Vac, 47~63Hz |
Inrush Current | Single-Phase and 3-Phase 208V models: Less than 50A |
Power Factor | Single Phase models: 0.99@230Vac, rated output power. 3-Phase models: 0.94@208Vac, rated output power. |
Parallel Operation | Up to 4 identical units in master/slave mode |
Series Operation | Up to 2 identical units. with external diodes. 600V Max to Chassis ground |
Operating temp | 0~50°C, 100% load. |
Storage temp | -20~85°C |
Operating humidity | 20~90% RH (non-condensing). |
Storage humidity | 10~95% RH (non-condensing). |
Vibration | MIL-810F, method 514.5 , The EUT is fixed to the vibrating surface. |
Shock | Less than 20G , half sine, 11mSec. Unit is unpacked. |
Altitude | Operating: 10000ft (3000m), Derate output current by 2%/100m above 2000m, Alternatively, derate maximum ambient temp. |
by 1ºC/100m above 2000m. Non operating: 40000ft (12000m). | |
RoHS Compliance | Complies with the requirements of RoHS directive. |
Selecting the right power supply for your application is not a small task. Let our technical sales engineers guide you through the process of choosing the right solution for your needs.
Below some parameters usually required to size and select the right power supply:
Contact our team of experienced engineers to discuss your unique power conversion and backup needs. We offer a wide range of highly reliable components that can be integrated and customized to create a solution that meets or exceeds your requirements.
For power automation systems please contact us at power.systems.automation@heliosps.com.au