SKUStock Power AC/DC Input Voltage AC/DC Output Voltage 1 AC/DC PriceQuantity
HWS300-34300W88 - 264VAC3.3V $435.00
spinner
HWS300-123300W88 - 264VAC12V $435.00
spinner
HWS300-481300W88 - 264VAC48V $435.00
spinner
HWS1500-1201500W88 - 264VAC12V $1,763.00
spinner
HWS1500-4811500W88 - 264VAC48V $1,763.00
spinner

HWS300 – HWS1500 Series

AC/DC Power Supply Single Output: 300W – 1500W

The highly reliable 300W, 600W, 1000W and 1500W fan cooled models form part of a very broad HWS product offering ranging from 3.3V to 60V outputs. A 1-6V program input (on select models) can adjust the output from 20-120% of nominal for applications requiring non-standard voltages. Certifications include IEC/EN/UL 60950-1 and UL 508 (most HWS300, 600 models)

Key Market Segments & Applications

  • Factory Automation
  • Test & Measurement
  • Automated Service
WeightN/A
DimensionsN/A

SERIES TABLE

ModelVoltage VMax Curr. AEff. Typ (1)%
HWS300-33.3V6074/77
HWS600-33.3V12075/78
HWS1000-33.3V20071/73
HWS1500-33.3V30072/75
HWS300-55V6079/82
HWS600-55V12080/83
HWS1000-55V20076/78
HWS1500-55V30077/81
HWS1000-66V16779/81
HWS1500-66V25079/82
HWS1000-77.5V13480/82
HWS1500-77.5V20081/83
HWS300-1212V2780/83
HWS600-1212V5380/83
HWS1000-1212V8882/85
HWS1500-1212V12582/85
HWS300-1515V2280/83
HWS600-1515V4381/84
HWS1000-1515V7083/85
HWS1500-1515V10083/87
HWS300-2424V1482/85
HWS600-2424V2782/85
HWS1000-2424V4685/87
HWS1500-2424V65/70 (1)84/88
HWS1000-3636V30.785/88
HWS1500-3636V42/46.5 (1)84/88
HWS300-4848V782/85
HWS600-4848V1383/86
HWS1000-4848V2386/88
HWS1500-4848V3286/90
HWS1000-6060V18.485/88
HWS1500-6060V2886/90
(1) 100/220 VAC

SPECIFICATIONS TABLE

Input Voltage Range85 – 265VAC or 120 – 330VDC
Input Current (Typ)SEE DATASHEET
Inrush Current20/ 40
Power FactorMeets EN61000-3-2
Temperature Coefficient<0.02%/°C
Overcurrent Protection>105%
Overvoltage ProtectionYes (see datasheet)
Hold Up Time (Typ)20ms(HWS1500-7 – 16ms)
Leakage Current (max)<0.5mA (Typ 0.2mA at 100VAC, 0.4mA at 230VAC)
IndicatorGreen LED = ON
Operating Temperature-10 to +70°C, derate linearly to 50% load from 50 to 70 (2, 3)
Storage Temperature-30 to +85°C
Humidity (non condensing)Operating: 10 –  90%RH, Non operating 10 – 95%RH
CoolingInternal fan
Withstand VoltageInput to Ground 2.5kVAC, Input to Output 3kVAC, Output to Ground 500VAC for 1 min.
Isolation Resistance>100M at 25°C & 70%RH, Output to Ground 500VDC
Vibration (non operating)10 – 55Hz (1 minute sweep), 19.6m/s2 constant X, Y, Z 1 hour
Shock< 196.1 m/s2
Safety Agency ApprovalsUL60950-1, CSA60950-1, EN60950-1, EN50178, UL508, CE Mark
Line DipComplies with SEMI F47 (200VAC line only)
Conducted & Radiated EMIEN55011 / EN55022-B, FCC-B, VCCI-B
ImmunityIEC61000-4-2, -3, -4, -5, -6, -8, -11; IEC61000-6-2
Weight (Typ)SEE DATASHEET
Size (HxWxD) (with cover)SEE DATASHEET
MTBFSEE DATASHEET

Ask for Assistance

Selecting the right power supply for your application is not a small task. Let our technical sales engineers guide you through the process of choosing the right solution for your needs.

Below some parameters usually required to size and select the right power supply:

  • Power & control requirements
  • Output & Input Voltage / Multioutput Voltage / Variable Voltage
  • Redundancy level
  • Mounting
  • Inrush Current
  • Environmental specifications (Temperature, altitude, vibration, shock)
  • Specific Industries Standards (Railway, Military, Medical)