HWS300 – HWS1500 – AC/DC Single Output: 300W – 1500W

The highly reliable 300W, 600W, 1000W and 1500W fan cooled models form part of a very broad HWS product offering ranging from 3.3V to 60V outputs. A 1-6V program input (on select models) can adjust the output from 20-120% of nominal for applications requiring non-standard voltages. Certifications include IEC/EN/UL 60950-1 and UL 508 (most HWS300, 600 models)

SERIES TABLE

Model Voltage V Max Curr. A Eff. Typ (1)%
HWS300-3 3.3V 60 74/77
HWS600-3 3.3V 120 75/78
HWS1000-3 3.3V 200 71/73
HWS1500-3 3.3V 300 72/75
HWS300-5 5V 60 79/82
HWS600-5 5V 120 80/83
HWS1000-5 5V 200 76/78
HWS1500-5 5V 300 77/81
HWS1000-6 6V 167 79/81
HWS1500-6 6V 250 79/82
HWS1000-7 7.5V 134 80/82
HWS1500-7 7.5V 200 81/83
HWS300-12 12V 27 80/83
HWS600-12 12V 53 80/83
HWS1000-12 12V 88 82/85
HWS1500-12 12V 125 82/85
HWS300-15 15V 22 80/83
HWS600-15 15V 43 81/84
HWS1000-15 15V 70 83/85
HWS1500-15 15V 100 83/87
HWS300-24 24V 14 82/85
HWS600-24 24V 27 82/85
HWS1000-24 24V 46 85/87
HWS1500-24 24V 65/70 (1) 84/88
HWS1000-36 36V 30.7 85/88
HWS1500-36 36V 42/46.5 (1) 84/88
HWS300-48 48V 7 82/85
HWS600-48 48V 13 83/86
HWS1000-48 48V 23 86/88
HWS1500-48 48V 32 86/90
HWS1000-60 60V 18.4 85/88
HWS1500-60 60V 28 86/90
(1) 100/220 VAC

SPECIFICATIONS TABLE

Input Voltage Range 85 – 265VAC or 120 – 330VDC
Input Current (Typ) SEE DATASHEET
Inrush Current 20/ 40
Power Factor Meets EN61000-3-2
Temperature Coefficient <0.02%/°C
Overcurrent Protection >105%
Overvoltage Protection Yes (see datasheet)
Hold Up Time (Typ) 20ms(HWS1500-7 – 16ms)
Leakage Current (max) <0.5mA (Typ 0.2mA at 100VAC, 0.4mA at 230VAC)
Indicator Green LED = ON
Operating Temperature -10 to +70°C, derate linearly to 50% load from 50 to 70 (2, 3)
Storage Temperature -30 to +85°C
Humidity (non condensing) Operating: 10 –  90%RH, Non operating 10 – 95%RH
Cooling Internal fan
Withstand Voltage Input to Ground 2.5kVAC, Input to Output 3kVAC, Output to Ground 500VAC for 1 min.
Isolation Resistance >100M at 25°C & 70%RH, Output to Ground 500VDC
Vibration (non operating) 10 – 55Hz (1 minute sweep), 19.6m/s2 constant X, Y, Z 1 hour
Shock < 196.1 m/s2
Safety Agency Approvals UL60950-1, CSA60950-1, EN60950-1, EN50178, UL508, CE Mark
Line Dip Complies with SEMI F47 (200VAC line only)
Conducted & Radiated EMI EN55011 / EN55022-B, FCC-B, VCCI-B
Immunity IEC61000-4-2, -3, -4, -5, -6, -8, -11; IEC61000-6-2
Weight (Typ) SEE DATASHEET
Size (HxWxD) (with cover) SEE DATASHEET
MTBF SEE DATASHEET

Related Products