$132.00 – $250.00
SKU | Stock | Power AC/DC | Input Voltage AC/DC | Output Voltage 1 AC/DC | Price | Quantity | ||
---|---|---|---|---|---|---|---|---|
RWS300B-5 | 1 | 300W | 88 - 264VAC | 5V | $132.00 | |||
RWS300B-12 | 0 | 300W | 88 - 264VAC | 12V | $132.00 | |||
RWS300B-15 | 12 | 300W | 88 - 264VAC | 15V | $132.00 | |||
RWS300B-24 | 1 | 300W | 88 - 264VAC | 24V | $132.00 | |||
RWS300B-36 | 1 | 300W | 88 - 264VAC | 36V | $132.00 | |||
RWS300B-48 | 4 | 300W | 88 - 264VAC | 48V | $132.00 | |||
RWS600B-5 | 1 | 600W | 88 - 264VAC | 5V | $250.00 | |||
RWS600B-15 | 3 | 600W | 88 - 264VAC | 15V | $250.00 | |||
RWS600B-24 | 0 | 600W | 88 - 264VAC | 24V | $250.00 | |||
RWS600B-36 | 0 | 600W | 88 - 264VAC | 36V | $250.00 | |||
RWS600B-48 | 5 | 600W | 88 - 264VAC | 48V | $250.00 |
Offering solid performance at a reasonable price, the RWS-B series of 50W to 600W power supplies feature 10 year electrolytic capacitor lifetimes, ensuring long field life. The products are backed by a seven-year warranty and are available with output voltages from 5 to 48V. All RWS-B models operate from a universal AC input of 85 – 265V (300V for 5 seconds) to meet a wide range of applications, including industrial, test & measurement, broadcast, communications and LED signage.
Weight | N/A |
---|---|
Dimensions | N/A |
Model | Voltage | Adjust Range (V) | Max Current (A) | Efficiency (typ) % 115/230VAC |
RWS50B-5 | 5V | 4.5-5.75 | 10 | 78 / 79 |
RWS100B-5 | 5V | 4.5-5.75 | 14 | 77.5 / 79 |
RWS150B-5 | 5V | 4.5-5.75 | 21 | 77.5 / 79.5 |
RWS300B-5 | 5V | 4.5-5.75 | 50 | 75 / 78.5 |
RWS600B-5 | 5V | 4.5-5.75 | 100 | 74 / 77.5 |
RWS50B-12 | 12V | 10.8-13.8 | 4.3 | 83 / 84 |
RWS100B-12 | 12V | 10.8-13.8 | 8.5 | 83 / 84 |
RWS150B-12 | 12V | 10.8-13.8 | 13 | 84.5 / 87.5 |
RWS300B-12 | 12V | 10.8-13.8 | 25 | 79.5 / 82.5 |
RWS600B-12 | 12V | 10.8-13.8 | 50 | 82 / 84.5 |
RWS100B-15 | 15V | 13.5-17.25 | 6.8 | 84 / 85 |
RWS150B-15 | 15V | 13.5-17.25 | 10 | 84.5 / 87.5 |
RWS300B-15 | 15V | 13.5-17.3 | 20 | 81.5 / 84.5 |
RWS600B-15 | 15V | 13.5-17.3 | 40 | 82 / 84.5 |
RWS50B-24 | 24V | 21.6-27.6 | 2.2 | 86 / 87 |
RWS100B-24 | 24V | 21.6-27.6 | 4.5 | 86 / 87.5 |
RWS150B-24 | 24V | 21.6-27.6 | 6.5 | 86.5 / 89.5 |
RWS300B-24 | 24V | 21.6-27.6 | 12.5 | 85 / 88 |
RWS600B-24 | 24V | 21.6-27.6 | 25 | 85 / 88.5 |
RWS150B-28 | 28V | 25.2-32.2 | 5.4 | 86.5 / 89.5 |
RWS300B-36 | 36V | 32.4-41.4 | 8.4 | 85 / 88 |
RWS600B-36 | 36V | 32.4-41.4 | 16.7 | 84 / 88.5 |
RWS50B-48 | 48V | 43.2-52.8 | 1.1 | 87 / 88 |
RWS100B-48 | 48V | 43.2-52.8 | 2.1 | 86 / 87 |
RWS150B-48 | 48V | 43.2-52.8 | 3.3 | 86.5 / 89.5 |
RWS300B-48 | 48V | 43.2-52.8 | 6.3 | 85 / 88 |
RWS600B-48 | 48V | 43.2-52.8 | 12.5 | 85 / 88.5 |
AC Input Voltage range | 85 – 265VAC (47 – 63Hz), 300VAC for 5 seconds |
Power Factor (100 / 200VAC) | Meets EN61000-3-2 |
Input Current (115/230VAC) (typ) | See Datasheet |
DC Input | See Datasheet |
Temperature Coefficient | <0.02%/°C |
Regulation | See table series |
Overcurrent Protection | >105%, 5V & 12V constant current limit & hiccup autorecovery, 24V &48V constant current limit with autorecovery |
Overvoltage Protection | 115-140%, Cycle AC line to reset |
Hold Up Time (typ at full load) | 20ms |
Leakage Current (max) | 750uA maximum, typically 175uA at 115VAC, 63Hz |
Operating Temperature (1) | -10° to +70°C, derate above 45°C for 50W, 40°C for 100W & 150W, 50°C for 300W & 600W (see graphs below) |
Storage Temperature | -30° to +75°C |
Operating Humidity (non condensing) | 30 – 90 |
Storage Humidity (non condensing) | 33147 |
Withstand Voltage | Input to Ground 2kVAC, Input to Output 3kVAC, Output to Ground 500VAC for 1 min. |
Isolation Resistance | >100M at 25°C & 70%RH, Output to Ground 500VDC |
Vibration (non operating) | 10 – 55Hz: 19.6m/s2 (sweep 1 min) X, Y, Z for 1 hour |
Shock | < 196.1 m/s2 |
Safety Agency Approvals (2) (3) | UL60950-1, CSA60950, EN60950-1, UL:508, CSA C22.2 No.107.1-01, CE Mark |
Conducted & Radiated EMI | EN55011 / EN55022-B, FCC Class B, VCCI-B |
Immunity | IEC61000-4-2, -3, -4, -5, -6, -8, -11 |
(1) RWS600B operates down to -20°C. (2) UL508 & CSA C22.2 No.107.1-01 on RWS50B-5, -12, -24, RWS100B-5, -12, -24, RWS150B-5, -12, -24 & RWS300B-24 only. (3) Consult Sales Office for use under DC Input conditions. |
Selecting the right power supply for your application is not a small task. Let our technical sales engineers guide you through the process of choosing the right solution for your needs.
Below some parameters usually required to size and select the right power supply:
Email us at sales@heliosps.com.au, we will get back as soon as we can.