iHP Modular High Power System-Up to 24000 Watts

Designed for a wide range of medical and industrial applications, Artesyn’s iHP configurable intelligent power system provides accuracy, resolution and stability as either a programmable voltage or current source. It provides up to 24 kW in 3 kW increments and can be configured for up to 8 outputs using a wide variety of plug-in modules that address a large range of voltages and currents.

Safety approvals secured by Artesyn eliminate the need for an isolation transformer in medical equipment. The iHP power system also has industrial safety approvals, including compliance to the SEMI F47 standard for semiconductor processing equipment.In horticultural LED lighting, bulk high voltage current sources eliminate the need for individual LED array drivers and reduce installation and operating costs. For chemical processing and water treatment applications, the compact size and multi-rack paralleling of the iHP series can accommodate large installations up into the Megawatt range. The unit’s software interface can be programmed to run sophisticated process flows. Standard modules provide a wide range of bulk power as input to laser drivers. For laboratory equipment, precision modules in development provide low noise and accurate control of voltage and current source with built-in wireless communication to a remote control panel. For electroplating and etching applications, Artesyn is developing modules to provide enhanced programmable rise and fall times coupled with a high-level software interface that can be tailored to exact process requirements.

The iHP power system offers developers either an analog or digital interface to their system supporting standard communications protocols, while a software graphical user interface (GUI) allows for easy configuration.

  • Versatile input configurable to: Low line 180-264 Vac single phase and 3-phase & High line 342-528 Vac 3-phase
  • Medical safety approved – NO ISOLATION XFMR NEEDED
  • Flexible control interfaces
  • Air cooled

iHP12 Electrical Specifications

iHP12 Electrical Specifications
Input Parameter 19” Rack 12 KW strapped as
1-phase 200/220/230/240 Vac
Nominal (iHP12L1A)
Type: 19” Rack 12 KW strapped as
3-phase 200/208/240 Vac Nominal
(iHP12L3A)
Type: 19” Rack 12 KW strapped
as 3-phase 380/480 Vac Nominal
(iHP12H3A)
Input range 180 Vac to 264 Vac
(Nominal rating 200/220/230/240 Vac)
180 Vac to 264 Vac
(Nominal rating 200/208/240 Vac)
342 Vac to 528 Vac
(Nominal rating 380/480 Vac)
Number of phases 1-phase 3-wire total (2-phase and 1
protective earth ground)
3-phase (Wye or Delta)
4-wire total (3-phase and
1 protective earth ground)
3-phase (Wye or Delta)
4-wire total (3-phase and
1 protective earth ground)
Frequency 47-63 Hz 47-63 Hz 47-63 Hz
Phase detection NA Loss of phase will inhibit unit off.
Housekeeping/comms must continue with phase loss.
Loss of phase will inhibit unit off.
Housekeeping/comms must continue with phase loss.
Max current/phase 75 A @ 180 Vac 44 A @ 180 Vac 23 A @ 342 Vac
19 A @ 432 Vac
Power factor > 0.99 @ full load and nominal line > 0.98 @ full load and nominal line > 0.98 @ full load and nominal line
Rack parallel Up to 6 racks (72 KW) Up to 6 racks (72 KW) Up to 6 racks (72 KW)
Efficiency > 91% @ 1P 240 Vac full load
> 90% @ 1P 208 Vac/200 Vac full load
> 91% @ 3P 240 Vac full load
> 90% @ 3P 208 Vac/200 Vac full load
> 90% @ 3P 380 Vac full load
> 91% @ 3P 480 Vac full load
Standby regulation 4.75 – 5.25 V 4.75 – 5.25 V 4.75 – 5.25 V

iHP24 Electrical Specifications

iHP24 Electrical Specifications
Input Parameter 19” Rack 24 KW strapped as
3-phase 380/480 Vac Nominal
(iHP24H3A/L)
19” Rack 24 KW strapped as
3-phase 208/240 Vac Nominal
(iHP24L3A/L)
Input range 342 Vac to 528 Vac
(Nominal rating 380/480 Vac)
187.5 Vac to 264 Vac
(Nominal rating 208/240 Vac)
Number of phases 3-phase (Wye or Delta) 4 wire total (3-phase and 1 protective earth ground) 3-phase (Wye or Delta) 4 wire total (3-phase and 1 protective earth ground)
Frequency 47-63 Hz 47-63 Hz
Phase detection Loss of phase will inhibit unit off.
Housekeeping/comms must continue with phase loss.
Loss of phase will inhibit unit off.
Housekeeping/comms must continue with phase loss.
Max current/phase 51 A @ 342 Vac
40 A @ 432 Vac
84 A @ 187.5 Vac
Power factor > 0.98 @ full load and nominal line > 0.98 @ full load and nominal line
Rack parallel Up to 6 racks (144 KW) Up to 6 racks (144 KW)
Efficiency > 90% @ 3P 380 Vac full load
> 91% @ 3P 480 Vac full load
> 91% @ 3P 240 Vac full load
> 90% @ 3P 208 Vac 3P full load
Standby regulation 4.75 – 5.25 V 4.75 – 5.25 V