Our website features a wide range of standard power conversion and backup products, but we also have the capacity and capability to design and manufacture custom solutions to meet your specific application needs. Contact our team of experienced engineers today to discuss your project. Dismiss
The BW54 Series is a new generation / smart Power Supply that is designed to provide battery backed-up power in the event of either the PSU or the battery being disconnected or short circuited. When the AC supply fails, the battery will automatically be connected and will provide power until the ac supply is restored.. If the battery has reached it’s disconnect voltage, it will automatically be disconnected to prevent deep discharge damage.
Designed for powering critical loads with battery back-up, in a wide range of Industrial applications and in particular Security installations and Access Control, with separate Load and Battery Charging circuits.
A wide range of Signals, LEDs and Alarms, all aimed at a providing the optimum solution for powering critical DC Loads.
An isolated Common Fault relay has been provided which will operate if any fault is found (This is a fail-safe signal so will signal a fault even if no power sources are on/connected).
Model | Output Nom | Float V | Charger A | Power |
BW5475-12 | 12 V | 13.8 V | 1.0A | 75W |
BW54100-12 | 12 V | 13.8 V | 1.4A | 100W |
BW54140-12 | 12 V | 13.8 V | 2.0A | 140W |
BW5475-24 | 24 V | 27.6 V | 0.6A | 75W |
BW54140-24 | 24 V | 27.6 V | 1.0A | 140W |
Input Voltage | 240Vac ( 200~264 ) |
Input Frequency | 47 ~ 63Hz |
Input Fuse | Yes |
Hold Up Time | 30ms @ 230Vac input, full load and no battery connected. |
Power Factor | 0.42 @ 230Vac and full load |
No load Power | <5W |
Start up Time | Typically 1.5 seconds |
Output Voltage | 13.8V / 27.6V Refer to table |
Output Current | Refer to table |
Power Limit | Typically at 115% |
Efficiency | 80-85% @ 230Vac and full load |
OVP | 105-125% latching. Recycle input after 30 seconds to restar |
Short Circuit Protection | Hiccup mode |
Current Limit | Primary side power limited |
Thermal Protection | Primary side ( non-latching ) |
Operating Temp. | -10ºC to +70ºC (Derate 2.5% / ºC above 50ºC) |
Cooling | Convection cooled |
Humidity | 10-95% non-condensing |
Ripple & Noise | 0.5% @ 230Vac , full load ( BW =DC-10Hz) |
Safety | EN60950, Class I |
Insolation | Input – Output / Case: 2200Vdc |
EMC | EN55022 Class B Conducted EN55022 Class A Radiated |
Immunity | EN61000-3-2 Class A Harmonics EN61000-4-4 Fast TransientsEN61000-4-5 Surge EN61000-4-11 Voltage Dips |
Selecting the right power supply for your application is not a small task. Let our technical sales engineers guide you through the process of choosing the right solution for your needs.
Below some parameters usually required to size and select the right power supply:
Contact our team of experienced engineers to discuss your unique power conversion and backup needs. We offer a wide range of highly reliable components that can be integrated and customized to create a solution that meets or exceeds your requirements.
For power automation systems please contact us at power.systems.automation@heliosps.com.au
© Copyright Helios Power Solutions 2024