Our website features a wide range of standard power conversion and backup products, but we also have the capacity and capability to design and manufacture custom solutions to meet your specific application needs. Contact our team of experienced engineers today to discuss your project. Dismiss
$203.00
SKU | Stock | Power DC/DC | Input Voltage DC/DC | Output Voltage 1 DC/DC | Price | Quantity | ||
---|---|---|---|---|---|---|---|---|
DTE4048S24 | 4 | 40W | 18-75V | 24V | $203.00 |
Weight | 0.162 kg |
---|---|
Dimensions | 112 × 63.8 × 25.6 mm |
Input | |
Input Voltage Range | 9-36VDC 24V nominal 18-75VDC 48V nominal |
Input Current | See Models and Ratings table |
Undervoltage Lockout | On at >9 V. O <7.5 V – 24V models On at >18 V. O <16.0 V – 48V models |
Input Surge | 50 VDC 24 V models for 100 ms 100 VDC 48V models for 100 ms |
Remote On/O | On: Logic High (3.5-12 V) or open circuit Off: Logic Low (<1.2 V) or short pin 1 to pin 2 |
Output | |
Output Voltage | 5.1 – 48V See Models and Ratings table |
Minimum Load | No minimum load required |
Start Up Delay | 50 ms |
Ripple & Noise | 100 mV pk-pk – 5.1 V model, 20 MHz bandwidth 150 mV pk-pk – 12 V & 48 V models, 20 MHz bandwidth 200 mV pk-pk – 48 V model, 20 MHz bandwidth |
Short Circuit Protection | Trip & Restart (hiccup mode), auto recovery |
Overload Protection | 150 % Trip & Restart (hiccup mode) |
Overvoltage Protection | 120 % Zener diode clamp |
Temperature Coe cient | 0.02 %/ °C |
General | |
Effciency | 90% See Models and Ratings table |
Isolation | 2500 VDC For 60 s |
Isolation Resistance | 1000 MΩ At 500 VDC |
Input to Output Capacitance | 2400 pF |
Switching Frequency | 285 kHz |
Environmental | |
Operating Temperature | -40 +85°C See derating curve |
Storage Temperature | -50 +125°C |
Case Temperature | 95°C |
Humidity | 5-95%RH Non-condensing |
Cooling | Natural convection |
Shock | ±3 shocks in each plane, total 18 shocks of 30 g : 11 ms halfsine. Conforms to EN60068-2-27 & EN60068-2-47 |
Vibration | 10-500 Hz at 2 g sweep and endurance at resonance in all 3 planes. Conforms to EN60068-2-6 |
Model Name | Input | Output | Power |
DTE4024S5V1 | 9 to 36 VDC | 5.1 V / 8 A | 40W |
DTE4024S12 | 9 to 36 VDC | 12 V / 3.33 A | 40W |
DTE4024S24 | 9 to 36 VDC | 24 V / 1.67 A | 40W |
DTE4024S48 | 9 to 36 VDC | 48 V / 0.835 A | 40W |
DTE4048S5V1 | 18 to 75 VDC | 5.1 V / 8 A | 40W |
DTE4048S12 | 18 to 75 VDC | 12 V / 3.33 A | 40W |
DTE4048S24 | 18 to 75 VDC | 24 V / 1.67 A | 40W |
DTE4048S48 | 18 to 75 VDC | 48 V / 0.835 A | 40W |
Selecting the right power supply for your application is not a small task. Let our technical sales engineers guide you through the process of choosing the right solution for your needs.
Below some parameters usually required to size and select the right power supply:
Contact our team of experienced engineers to discuss your unique power conversion and backup needs. We offer a wide range of highly reliable components that can be integrated and customized to create a solution that meets or exceeds your requirements.
For power automation systems please contact us at power.systems.automation@heliosps.com.au
© Copyright Helios Power Solutions 2023