GEN5Kw

Laboratory – Variable DC Power Supply

The Genesys™ 2U Full-Rack (GEN-2U) series of 5000W DC Programmable Power Supplies provides high power density (up to 5200W) with a complete set of user-friendly interfaces within a 2U profile.

This series offers Output voltages from 8V (@ 600A) to 600V (@ 8.5A) in both a Three-phase 208VAC Input (170-265VAC, 47-63Hz) and Three-phase 400VAC Input (342-460VAC, 47-63Hz) with Active Power-Factor Correction (0.94 @ rated load).

Multiple remote programming methods are available including the built-in Remote Analog Program/Monitor and Remote Digital Serial Communication (RS-232/RS-485) Interfaces along with the optional LXI certified LAN, IEEE (IEEE 488.2 & SCPI compliant), USB (2.0 compliant) and Isolated Analog (5V/10V and 4-20mA) Interfaces.

All models are CE Marked in accordance with the Low Voltage and EMC Directives, are RoHS compliant, have worldwide Safety Angency approvals (UL/cUL 60950-1 and EN 60950-1 listed) and offer a five (5) year Warranty.

SERIES TABLE

ModelOutput Voltage (VDC)Output Current ( A )Output Power ( W )
GEN 8-6000~8V0~6004800
GEN 10-5000~10V0~5005000
GEN 16-3100~16V0~3104960
GEN 20-2500~20V0~2505000
GEN 30-1700~30V0~1705100
GEN 40-1250~40V0~1255000
GEN 60-850~60V0~855100
GEN 80-650~80V0~655200
GEN 100-500~100V0~505000
GEN 150-340~150V0~345100
GEN 200-250~200V0~255000
GEN 300-170~300V0~175100
GEN 400-130~400V0~135200
GEN 500-100~500V0~105000
GEN 600-8.50~600V0~8.55100

SPECIFICATIONS TABLE

Input Voltage / Frequency (range)3-Phase, 208V models: 170~265Vac,  47~63Hz , 3-Phase, 400V models: 342~460Vac, 47~63Hz
Inrush Current3-Phase 208V models: Less than 50A, 3-Phase 400V models: Less than 20A
Power Factor3-Phase models: 0.94@208/380Vac, rated output  power.
Parallel OperationUp to 4 identical units in master/slave mode
Operating temp0~50°C, 100% load.
Storage temp-20~85°C
Operating humidity20~90% RH (non-condensing).
Storage humidity10~95% RH (non-condensing).
VibrationMIL-810F, method 514.5, The EUT is fixed to the vibrating surface.
ShockLess than 20G, half sine, 11mSec. Unit is unpacked.
AltitudeOperating: 10000ft (3000m), Derate output current by 2%/100m above 2000m, Alternatively, derate maximum ambient temp.
by 1ºC/100m above 2000m. Non operating: 40000ft (12000m).
RoHS ComplianceComplies with the requirements of RoHS directive.

Ask for Assistance

Selecting the right power supply for your application is not a small task. Let our technical sales engineers guide you through the process of choosing the right solution for your needs.

Below some parameters usually required to size and select the right power supply:

  • Power & control requirements
  • Output & Input Voltage / Multioutput Voltage / Variable Voltage
  • Redundancy level
  • Mounting
  • Inrush Current
  • Environmental specifications (Temperature, altitude, vibration, shock)
  • Specific Industries Standards (Railway, Military, Medical)
  • Terminals

Contact Our Team

Contact our team of experienced engineers to discuss your unique power conversion and backup needs. We offer a wide range of highly reliable components that can be integrated and customized to create a solution that meets or exceeds your requirements.

For power automation systems please contact us at power.systems.automation@heliosps.com.au

You may also like...