The Genesys™ Full-Rack (GEN-1U) series of DC Programmable Power Supplies provides high power density (up to 780W/1560W) with a complete set of user-friendly interfaces within a 1U full-rack profile. It offers Output voltages from 6V (@ 100A/200A) to 600V (@ 1.3A/2.6A) and a wide-range AC Input (85-265VAC, 47/63Hz) with Active Power-Factor Correction (0.99 @ rated load).
These units can operate in either Constant-Current (CC) or Constant-Voltage (CV) mode with a user-friendly front panel interface (continuous encoders for FINE and COARSE adjustment and four-digit LED Voltage and Current meters) and provide safety features such as Safe/Auto Re-Start, Last Setting Memory and built-in protective functions (OVP, UVL, Current FOLDback, OTP and AC Low-Line).
Multiple remote programming/monitor/control methods are available including the built-in J1 Remote Analog and the RS232/RS485 Multi-Drop Remote Digital Interface (where up to 31 units may be controlled). Other Optional Remote Digital Interfaces (LAN, IEEE and USB) and Isolated Analog (5V/10V and 4-20mA) Interfaces are optional and factory installed (one per power supply). Instrument Software Drivers (NI LabView and NI LabWindows) are also available.
CSI SERIES DC-AC Inverters | |
---|---|
Power |
Model | Output Voltage (VDC) | Output Current ( A ) | Output Power ( W ) |
GEN6-100 | 0~6V | 0~100 | 600 |
GEN6-200 | 0~6V | 0~200 | 1200 |
GEN8-90 | 0~8V | 0~90 | 720 |
GEN8-180 | 0~8V | 0~180 | 1440 |
GEN12.5-60 | 0~12.5V | 0~60 | 750 |
GEN12.5-120 | 0~12.5V | 0~120 | 1500 |
GEN20-38 | 0~20V | 0~38 | 760 |
GEN20-76 | 0~20V | 0~76 | 1520 |
GEN30-25 | 0~30V | 0~25 | 750 |
GEN30-50 | 0~30V | 0~50 | 1500 |
GEN40-19 | 0~40V | 0~19 | 760 |
GEN40-38 | 0~40V | 0~38 | 1520 |
GEN50-30 | 0~50V | 0~30 | 1500 |
GEN60-12.5 | 0~60V | 0~12.5 | 750 |
GEN60-25 | 0~60V | 0~25 | 1500 |
GEN80-9.5 | 0~80V | 0~9.5 | 760 |
GEN80-19 | 0~80V | 0~19 | 1520 |
GEN100-7.5 | 0~100V | 0~7.5 | 750 |
GEN100-15 | 0~100V | 0~15 | 1500 |
GEN150-5 | 0~150V | 0~5 | 750 |
GEN150-10 | 0~150V | 0~10 | 1500 |
GEN300-2.5 | 0~300V | 0~2.5 | 750 |
GEN300-5 | 0~300V | 0~5 | 1500 |
GEN600-1.3 | 0~600V | 0~1.3 | 780 |
GEN600-2.6 | 0~600V | 0~2.6 | 1560 |
Input voltage/freq. (*1) | 85~265Vac continuous, 47~63Hz, single phase |
Power Factor | 0.99 @100/200Vac, rated output power. |
EN61000-3-2,3 compliance | Complies with EN61000-3-2 class A and EN61000-3-3 at 20~100% output power. |
Input current 100/200Vac | 750W :10.5A / 5A, 1500W :21A / 11A |
Inrush current 100/200Vac | 750W :Less than 25A, 1500 W :Less than 50A |
Hold-up time | More than 20mS, 100Vac, at 100% load |
Parallel Operation | Up to 4 units in master/slave mode with single wire current balance connection |
Series Operation | Up to 2 units. with external diodes. 600V Max to Chassis ground |
Operating temp | 0~50°C, 100% load |
Operating humidity | 30~90% RH (non-condensing) |
Vibration | MIL-810E, method 514.4, test cond. I-3.3.1. The EUT is fixed to the vibrating surface. |
Shock | Less than 20G, half sine, 11mSec. Unit is unpacked. |