The ZUP series are wide range output switching power supplies with laboratory performance. The ZUP series is power factor corrected and operates from worldwide AC voltage range continuously. Output voltage and current are continuously displayed and LED indicators show the complete operating status of the power supply.The front panel controls allow the user to set the output parameters, the protection levels (over-voltage / under-voltage)and arm the foldback protection to disable the output if the unit switches from Constant-voltage mode to Constant-current mode.

Control via the serial communication port

The following parameters can be programmed via the serial communication port:

  1.  Output voltage setting
  2. Output current setting
  3. Output On/Off
  4. Arming or release of the foldback protection
  5. Over-voltage protection setting
  6. ‘Soft’ under-voltage limit
  7.  Output voltage measurement
  8. Output current measurement
  9. Power supply start-up mode (last setting or safe mode)
  10. Over-voltage protection setting read
  11. Under-voltage limit read
  12. Remote/Local Control

Output connections

Output connections are made to rear panel bus-bars. Either the positive or negative terminal may be grounded or the output may be floated. The maximum potential (including the output voltage) that either output terminal is from ground must not exceed 60V. Local or remote sense may be used. In remote sense, the maximum voltage drop on each wire is 0.5V.

SERIES TABLE

Model Output Voltage ( VDC ) Output Current ( A ) Output Power ( W )
ZUP6-33 0 ~ 6 VDC 0 ~ 33 198
ZUP6-66 0 ~ 6 VDC 0 ~ 66 396
ZUP6-132 0 ~ 6 VDC 0 ~ 132 792
ZUP10-20 0 ~ 10VDC 0 ~ 20 200
ZUP10-40 0 ~ 10VDC 0 ~ 40 400
ZUP10-80 0 ~ 10VDC 0 ~ 80 800
ZUP20-10 0 ~ 20VDC 0 ~ 10 200
ZUP20-20 0 ~ 20VDC 0 ~ 20 400
ZUP20-40 0 ~ 20VDC 0 ~ 40 800
ZUP36-6 0 ~ 36VDC 0 ~ 6 216
ZUP36-12 0 ~ 36VDC 0 ~ 12 432
ZUP36-24 0 ~ 36VDC 0 ~ 24 864
ZUP60-3.5 0 ~ 60VDC 0 ~ 3.5 210
ZUP60-7 0 ~ 60VDC 0 ~ 7 420
ZUP60-14 0 ~ 60VDC 0 ~ 14 840
ZUP80-2.5 0 ~ 80VDC 0 ~ 2.5 200
ZUP80-5 0 ~ 80VDC 0 ~ 5 400
ZUP120-1.8 0 ~ 120VDC 0 ~ 1.8 216
ZUP120-3.6 0 ~ 120VDC 0 ~ 3.6 432

SPECIFICATIONS TABLE

INPUT VOLTAGE: 85 – 264VAC
FREQUENCY: 47 ~ 63Hz
INPUT CURRENT (@230VAC) ZUP200W: 1.5A
ZUP400W: 2.7A
ZUP800W: 5.4A
INPUT HARMONICS: Complies with EN61000-3-2
POWER FACTOR: Corrected @ 0.99
EFFICIENCY: Model dependent: 68~84%
LOAD REGULATION: 0.01%  +3mV (CV)
0.02%  +5mA (CC)
LINE REGULATION: 0.01%  +2mV (CV)
0.01%  +2mA (CC)
RIPPLE: 5mV rms (CV) 7.5-100mA (CC)
PROTECTION: • Over voltage
• Over temperature
• Over current foldback