Significantly upgraded in 2013, the HWS-A series now has a higher efficiency (up to 91%), a lighter weight and reduced off-load power draws. The HWS-A series has five power levels, 15W, 30W, 50W, 100W and 150W, and output voltages from 3.3 to 48V. The product is covered by a limited lifetime warranty – a first for the industry when announced in 2008 for the previous HWS generation series.

 

SERIES TABLE

Model Voltage  (V) Adjust Range (V) Max Current (A) Efficiency (typ) %
HWS15A-3/A 3.3V 2.97 – 3.96 3 70/71
HWS30A-3/A 3.3V 2.97 – 3.96 6 75/77
HWS50A-3/A 3.3V 2.97 – 3.96 10 76/78
HWS100A-3/A 3.3V 2.97 – 3.96 20 82/84
HWS150A-3/A 3.3V 2.97 – 3.96 30 82/84
HWS15A-5/A 5V 4.0 – 6.0 3 77/79
HWS30A-5/A 5V 4.0 – 6.0 6 80/82
HWS50A-5/A 5V 4.0 – 6.0 10 82/84
HWS100A-5/A 5V 4.0 – 6.0 20 84/86
HWS150A-5/A 5V 4.0 – 6.0 30 85/87
HWS15A-12/A 12V 9.6 – 14.4 1.3 80/83
HWS30A-12/A 12V 9.6 – 14.4 2.5 84/86
HWS50A-12/A 12V 9.6 – 14.4 4.3 83/85
HWS100A-12/A 12V 9.6 – 14.4 8.5 86/88
HWS150A-12/A 12V 9.6 – 14.4 13 85/88
HWS15A-15/A 15V 12.0 – 18.0 1 81/84
HWS30A-15/A 15V 12.0 – 18.0 2 85/87
HWS50A-15/A 15V 12.0 – 18.0 3.5 83/86
HWS100A-15/A 15V 12.0 – 18.0 7 86/88
HWS150A-15/A 15V 12.0 – 18.0 10 86/89
HWS15A-24/A 24V 19.2 – 28.8 0.65 82/85
HWS30A-24/A 24V 19.2 – 28.8 1.3 86/88
HWS50A-24/A 24V 19.2 – 28.8 2.2 84/87
HWS100A-24/A 24V 19.2 – 28.8 4.5 87/89
HWS150A-24/A 24V 19.2 – 28.8 6.5 88/90
HWS15A-48/A 48V 38.4 – 52.8 0.33 80/80
HWS30A-48/A 48V 38.4 – 52.8 0.65 82/83
HWS50A-48/A 48V 38.4 – 52.8 1.1 84/86
HWS100A-48/A 48V 38.4 – 52.8 2.1 88/90
HWS150A-48/A 48V 38.4 – 52.8 3.3 89/91

SPECIFICATIONS TABLE

Input Voltage Range 85 – 265VAC (47 – 63Hz) Withstands 300VAC for 5s or 120 – 370VDC*
Input Current (Typ)   (1) See Datasheet
Inrush Current 14 / 28
Power Factor Meets EN61000-3-2
Temperature Coefficient <0.02%/°C
Overcurrent Protection >105%
Overvoltage Protection Yes (see datasheet)
Hold Up Time (Typ) 20
Leakage Current (max) <0.5mA (Typ 0.2mA at 100VAC, 0.4mA at 230VAC)
Indicator Green LED = ON
Operating Temperature (with cover) -10°C to +70°C, derate from 50°C to 70°C (2)
Storage Temperature -30 to +85°C
Humidity (non condensing) Operating: 30 – 90%RH, Non operating 10 – 95%RH
Cooling Convection
Withstand Voltage Input to Ground 2kVAC, Input to Output 3kVAC, Output to Ground 500VAC for 1 min.
Isolation Resistance >100M at 25°C & 70%RH, Output to Ground 500VDC
Vibration (non operating) 10 – 55Hz (1 minute sweep), 19.6m/s2 constant X, Y, Z 1 hour
Shock < 196.1 m/s2
Safety Agency Approvals UL60950-1, CSA60950-1, EN60950-1, EN50178, UL508, CE Mark
Line Dip Complies with SEMI F47 (200VAC line only)
Conducted & Radiated EMI EN55011 / EN55022-B, FCC-B, VCCI-B
Immunity IEC61000-4-2, -3, -4, -5, -6, -8, -11; IEC61000-6-2
Weight (Typ) See Datasheet
Size (HxWxD) (with cover) See Datasheet
MTBF See Datasheet